مخزن.
تصفح
220V to 9VAC 2A EI Step-Down Transformer (Single Secondary)

220V to 9VAC 2A EI Step-Down Transformer (Single Secondary)

متوفرالملفّات والمحوّلاتتم التحقق قبل ٣ أسابيع

‏١٨٠ ج.م.‏

Micro Ohm

عرض موردين آخرين

الوصف

Overview 🔌 Single-secondary EI laminated step-down transformer converting 220–240 VAC mains to 9 VAC @ 2 A (≈18 VA). Suitable for linear PSUs, audio, hobby electronics, and general-purpose AC applications. This listing is for 9 VAC only (NOT 9‑0‑9) . See Transformer – Wikipedia for background. Key Features ⭐ Primary: 220–240 VAC, 50/60 Hz (Egypt mains compatible) Secondary: 9 VAC (RMS), 2 A (isolated) Approx. power: 18 VA Open-frame EI laminated core Lead colors/terminal style may vary by batch (assumption; verify before wiring) Detailed Specifications 📐 Parameter Value Notes Input (primary) 220–240 VAC, 50/60 Hz Live/Neutral only (no earth on primary terminals) Output (secondary) 9 VAC @ 2 A Single secondary; not center-tapped Power rating ≈18 VA Vrms × I Regulation Not specified Typical EI 10–20% at full load (assumption) Isolation Galvanically isolated Standard mains transformer construction Insulation class Not specified Check batch/supplier if critical Mounting Chassis / base mount Through-bolts or L‑brackets Pinout & Wiring 🧰 Side Terminals Function Primary P1 – P2 Connect 220–240 VAC (L/N) Secondary S1 – S2 9 VAC output (isolated) Performance & Calculations 📊 Approx. DC after bridge + capacitor (no load): VDC ≈ Vrms·√2 − 2·Vf → 9·1.414 − ~1.4 ≈ ≈11.3 V . Ripple capacitor sizing (50 Hz mains, full-wave): C ≈ I/(2·f·ΔV) . Example for 2 A, ΔV=1 V: C ≈ 2/(2·50·1) = 20,000 µF . Use appropriate bridge rectifier and fuse. See Rectifier – Wikipedia . Applications ⚙️ Linear DC supplies (with bridge + filter), low‑voltage AC loads, small amplifiers, Arduino/MCU projects via regulator, sensors and relays (with rectification). Installation & Safety 🔒 Mains safety required. Isolate primary, add primary fuse/thermal fuse, strain relief, and earth the metal chassis if used. Keep primary/secondary wiring separated. Follow local electrical codes. Testing & Commissioning 🧪 No‑load test: apply 220–240 VAC, verify ~9 VAC RMS at S1–S2. Load test: draw up to 2 A and confirm voltage within regulation. DC build: add bridge + bulk capacitor; verify VDC and ripple. Attachments & Datasheets 📝 ]Background: Transformer – Wikipedia: https://en.wikipedia.org/wiki/Transformer Videos ▶️ Transformers Explained – The Engineering Mindset: https://www.youtube.com/watch?v=jcY4QN7awEc Bridge Rectifier with Capacitor Filter: https://www.youtube.com/watch?v=EfSW_9lx1VE Bridge Capacitor Value Calculation: https://www.youtube.com/watch?v=J9HsLWmtBnE Dimensions Not specified by suppliers; verify physical size before final enclosure design. نظرة عامة 🔌 محول EI خافض بملف ثانوي واحد يحوّل 220–240 فولت AC إلى 9 فولت AC عند 2 أمبير (≈18 VA). مناسب لمزودات الطاقة الخطية والتطبيقات العامة. الموديل ده 9 فولت فقط (مش 9‑0‑9) . المميزات ⭐ المدخل: 220–240 فولت، 50/60 هرتز المخرج: 9 فولت AC (RMS) عند 2 أمبير قدرة تقريبية: 18 VA قلب صفائح نوع EI ألوان الأسلاك/أطراف التثبيت بتختلف حسب التشغيلة (افتراض—اتأكد قبل التوصيل) المواصفات التفصيلية 📐 البند القيمة ملاحظات المدخل 220–240 VAC يوصل على L/N فقط المخرج 9 VAC عند 2 A ثانوي مفرد القدرة ≈18 VA Vrms × I التنظيم غير مذكور عادة 10–20% عند الحمل الكامل (افتراض) العزل معزول جلفانيًا ترانس تقليدي التوصيلات 🧰 الجانب الأطراف الوصف الابتدائي P1 – P2 دخول 220–240 VAC الثانوي S1 – S2 9 VAC الأداء والحسابات 📊 تقريب جهد DC بعد القنطرة والمكثف: VDC ≈ Vrms·√2 − 2·Vf ≈ 11.3 فولت (بدون حمل). تقدير المكثف: C ≈ I/(2·f·ΔV) → لحمل 2 A وتموج 1 فولت ≈ 20,000 µF. الاستخدامات ⚙️ مزودات DC خطية، أحمال AC منخفضة الجهد، دوائر تحكم، صوتيات بسيطة، مشاريع أردوينو بعد التقويم والتنظيم. التركيب والسلامة 🔒 اتبع اشتراطات السلامة مع الكهرباء العمومية، فيوز على الابتدائي، وعزل الأسلاك كويس. الاختبار والتشغيل 🧪 قِس الجهد بدون حمل ثم تحت الحمل، وبعد التقويم راقب الجهد والتموج.

من صفحة المورد.

عرض Micro Ohm

مخزن لا يبيع — كل عرض يفتح موقع المورد نفسه.

220V to 9VAC 2A EI Step-Down Transformer (Single Secondary) · مخزن