C3403C Quad Operational Amplifier 45nA PDIP-14
EGP 25
See other suppliers →Description
C3403C Quad Operational Amplifier 45nA PDIP-14 The pPC3403 is a monolithic Quad Operational Amplifier consisting of four independent high-gain, internally frequency-compensated operational amplifiers, designed to operate from a single power supply or split power supplies over a wide range of voltages. The common mode input range includes the negative supply thereby eliminating the necessity for external biasing components in many applications. Features Ultra-low input bias current: 45 nA typical Internal frequency compensation Common mode input voltage range includes V- Wide supply voltage range 3 V to 32 V (Single) 1.5 V to 16 V (Split) Class AB Output Stage for Minimal Crossover Distortion Output short circuit protection Specification Absolute Maximum Ratings Parameter Symbol μPC3403 Unit Voltage between V + and V − (Note 1) V + − V − −0.3 to +36 V Differential Input Voltage V ID ±30 Input Voltage (Note 2) V I V − −0.3 to V + +0.3 Output Voltage (Note 3) V O V − −0.3 to V + +0.3 Power Dissipation (C Package) (Note 4) P T 570 mW Power Dissipation (G2 Package) (Note 5) 550 Operating Temperature Range T opt −20 to +80 °C Storage Temperature Range T stg −55 to +125 Note 1. Reverse connection of supply voltage can cause destruction. Note 2. The input voltage should be allowed to input without damage or destruction. Even during the transition period of supply voltage, power on/off, etc., this specification should be kept. Normal operation will establish when both inputs are within the Common Mode Input Voltage Range of electrical characteristics. Note 3. This specification is the voltage that may be applied to the output terminal from external sources without damage or destruction. Even during supply-voltage transitions, power on/off, etc., this specification should be kept. The output voltage of normal operation will be the Output Voltage Swing of the electrical characteristics. Note 4. Thermal derating factor is −7.6 mW/°C when ambient temperature is higher than 50 °C. Note 5. Thermal derating factor is −5.5 mW/°C when ambient temperature is higher than 25 °C. Note 6. Pay careful attention to the total power dissipation not to exceed the absolute maximum ratings, Note 4 and Note 5. Recommended Operating Conditions Characteristic Symbol Min. Typ. Max. Unit Supply Voltage (Split) V ± ±1.5 – ±16 V Supply Voltage (V – = GND) V + +3 – +32 PINOUT Dimensions Applications Precision sensor interfaces (thermocouples, strain gauges). Battery-powered and portable instrumentation. Medical ECG/EEG front-end amplifiers. Low-current signal conditioning. Active filters and integrators. Data acquisition and precision measurement systems. Documents Datasheet CAD Files
From the supplier's page.
makhzan doesn't sell — every offer opens the supplier's own site.