
CONTEC MS100 SpO2 Simulator Pulse Rate Blood Oxygen Simulator Pulse Oximeter reaction time
EGP 70,000
See other suppliers →Description
CONTEC MS100 SpO2 Simulator Pulse Rate Blood Oxygen Simulator Pulse Oximeter reaction time The CONTEC MS100 SpO₂ Simulator is a small, lightweight, separated SpO₂ simulator designed for testing pulse oximeters under controlled simulated conditions. The simulator probe connects separately to the host, making testing more convenient, while built-in R-curves support compatibility with oximeters using different technologies. The CONTEC MS100 can simulate oxygen saturation, pulse rate, preset patient states, and different signal amplitudes. It can also test the performance of a pulse oximeter under different interference sources and measure the reaction time of the tested device. Its Alarm Limits function provides dedicated tests for SpO₂ alarm, pulse-rate alarm, and asystole, with the elapsed reaction time displayed in second The simulator supports a wide range of simulated SpO₂ values from 35% to 100% and pulse rates from 25 to 250 BPM. It can simulate different patient conditions, signal amplitudes, and interference sources, while built-in R-curves such as BCI, Masimo, and Nellcor improve compatibility with different pulse oximeter designs. The CONTEC MS100 can also test the reaction time of SpO₂, pulse rate, and cardiac-arrest detection. As different manufacturers may use different R-curve, current popular R curves (such as BCI, Masimo, Nellcor, etc.) are embedded into the simulator in advance. Features: Oxygen saturation simulation. Pulse-rate simulation. Preset patient-state simulation. Pulse oximeter reaction-time testing. SpO₂ alarm reaction-time testing. Pulse-rate alarm reaction-time testing. Asystole reaction-time testing. Different signal amplitude simulation. Different interference-source testing. Selectable R-curves. Separated simulator probe and host. 262K-color TFT display. Adjustable display brightness. Rechargeable lithium battery. Selectable key volume. 24 preset patient conditions. 8 patient conditions available as the default state. Multiple manufacturer R-curves. Specifications: Specification Value Brand CONTEC Model MS100 Product Type SpO₂ Simulator SpO₂ Simulation Range 35%–100% SpO₂ Resolution 1% SpO₂ Error ±2% or ±P, whichever is greater, from 50%–100% Pulse Rate Range 20–250 BPM Pulse Rate Resolution 5 BPM Pulse Rate Error ±1% ±1 BPM Amplitude Range 0.000%–20.000% Perfusion Index Adjustable Patient States 24 presetting conditions Default Patient States 8 R-Curves 10 built-in compatible R-curves Interference Simulation 50 Hz / 60 Hz and light interference Display 320 × 240 TFT Display Colors 262K Power Supply 3.7 V rechargeable lithium battery Battery Voltage Range 3.6–4.2 V Battery Quantity 1 × rechargeable lithium battery Battery Life ≥500 charge/discharge cycles Charging Adapter 5.0 V Reaction-Time Testing SpO₂, pulse rate, cardiac arrest Operation Film key-press Volume Key volume, selectable On/Off Weight 600g (with the lithium battery x1) Dimensions 189x125x41mm Main Parameters: SpO2 Measuring range: 35%~100% Resolution:1% Error: When SpO2 is 75%~100%, the error is the larger between ±2% and ±P(P denotes the precision of the tested oximeter); when SpO2 is 74%~50%, the error is the larger between ±2% and ±P; no define when SpO2 is less than 50%. Pulse rate Measuring range:20bpm~250bpm Resolution:5bpm Error:1%±1bpm Amplitude Measuring range:0.000%~20.000% Resolution:1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%. Patient state 24 conditions presetting and 8 conditions as default after start. The number of condition can be adjusted by Motion level setup. Voltage DC 3.6V~4.2V Power Supply Voltage 3.7 rechargeable lithium battery × 1 Battery working life Charge and discharge no less than 500 times. Function: Simulation of SpO2 and pulse rate. Support SpO2 and pulse rate simulation under 60 Hz/50 Hz interference and light interference. Adjustable perfusion index (PI), support SpO2 and pulse rate simulation under different PI. The reaction time of SpO2, PR and cardiac arrest can be tested. Built-in 10 compatible R curves (such as BCI, Masimo, Nellcor, etc.), meet the test requirements (R curve can be customized). Preset 24 patient states, such as weak pulse, bradycardia, hypoxia, infant, tachycardia, the aged, obesity, etc. Multiple language switching. Applications: Pulse oximeter testing. SpO₂ monitor testing. Pulse-rate monitor testing. SpO₂ alarm verification. Pulse-rate alarm verification. Asystole alarm testing. Reaction-time testing. Biomedical equipment testing. Medical equipment maintenance. Performance testing under interference conditions. Testing different oximeter technologies. Package Includes: 1 × CONTEC MS100 SpO₂ Simulator. 1 × MS100 User Manual. 1 × Power Adapter. 1 × Certificate. 1 × Simulator Probe. Documents: CONTEC MS100 Datasheet.
From the supplier's page.
makhzan doesn't sell — every offer opens the supplier's own site.