




Electromagnetic Relay MY3N-J 3PDT 5A 11Pin
From the shop's description
Features Plug-in Terminals, easy to exchange while mount on relay base Built-in operation indicators LED Specifications Poles & Throw: Triple Pole Double Throw Coil voltage: Optional Max Switching Current: 5 A at 240 VAC 5 A at 28 VDC Max Switching Voltage: 250 VAC, 125 VDC Contact: Contact materials: Ag Contact resistance: 50 mΩ max. Operation time: 20 ms max. Release time: 20 ms max. Maximum operating frequency: Mechanical – 18,000 operations/h Insulation resistance: 100 MΩ min. Ambient operating temperature: -55 to 60°C*2 Ambient operating humidity: 5% to 85% Environmental friendly product (RoHS compliant) Operating Coils Item Rated voltage (V) Rated current (mA) Coil resistance (Ω) Coil inductance (H) Must- operate voltage (V) Must- release voltage (V) Maximum voltage (V) Power consumption (VA, W) 50 Hz 60 Hz Armature OFF Armature ON AC 110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1 80% max. * 1 30% min. * 2 110% of rated voltage Approx. 0.9 to 1.1 (at 60 Hz) 220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4 DC 12 75 160 0.73 1.37 10% min. * 2 Approx. 0.9 24 36.9 650 ?3.2 5.72 Package Content 1 x MY3N-J Relay Relay Pin Terminals Another step for connecting a relay to the PCB covers the pin terminals and configuration of the relay. The standardized approach shown in the table identifies the terminals of electromagnetic relays. Terminal Terminal Description COIL One end of the coil – voltage connects to the terminal to supply power to the coil COIL One end of the coil – voltage connects to the terminal to supply power to the coil COM This is the output terminal of the relay where one end of the load circuit is connected. This terminal is internally connected with either of the other two terminals depending on the state of the relay. NO – Normally Open Connects to device that the relay will power when the coil receives sufficient voltage to energize. Device remains off when the relay has no power and switches on when the relay receives power. NC – Normally Closed Terminal connects to device to power when relay receives no power. Device remains on when the relay has no power and switches off when the relay receives power.
Read moreShow less
Similar products
XA2ED21 – Selector switch – ?22 – standard handle – 2 positions – 1NO, Schneider ElectricEGP 601 shopchecked 19 days ago
ON-OFF Double Push-Button Momentary Switch 29mm with LED LightEGP 601 shopchecked 16 days ago
Electromagnetic Relay LY2N-J DPDT 12VDC Coil 8 Pin with PTF08A SocketEGP 601 shopchecked 19 days ago
Song Chuan 812H-1C-C-12VDC Power Relay 12V 12A 5 PinEGP 601 shopchecked 14 days ago
XA2ED33 – Selector switch – Ø22 – standard handle – 3 positions – 2NO, Schneider ElectricEGP 601 shopchecked 19 days ago
RS26 Plum Blossom Rotary Selector Switch 4 Pole 12 Position 20MMEGP 601 shopchecked 12 days ago
ESP8266 ESP-01 5V WiFi Relay ModuleEGP 601 shopPrice may be out of date (75 days)
Miniature Power Relay HF49FD/005-1H11T 5V 5AEGP 601 shopchecked 17 days ago